Schneider/Actassi CAT-6A 10GIG 4PAIR CABLE LSZH 23AWG WHITE 500MTR (1640 FT)
Range | Actassi |
---|---|
Product or component type | Copper cable |
Cable packaging | Drum of 500 m |
Colour tint | Blue |
Cable shielding type | U/FTP |
Type of cable | 4 pair cables |
---|---|
Communication network category | 6A |
remote powering | PoE 15W (Power over Ethernet) PoE+ 30W (Power over Ethernet Plus) 4PPoE 100W (Power over Ethernet) |
Communication network type | 10GBASE-T |
Minimum return loss | Guaranteed: 20.1 dB at 100 MHz typical: 24.2 dB Guaranteed: 17.3 dB at 250 MHz typical: 22 dB Guaranteed: 17.3 dB at 500 MHz typical: 20.3 dB |
Attenuation | Guaranteed: 19.1 dB Typical: 17.5 dB @ 100 MHz Guaranteed: 31.1 dB Typical: 28.4 dB @ 250 MHz Guaranteed: 45.3 dB Typical: 41.4 dB @ 500 MHz |
Power sum near-end crosstalk [PSNEXT] | Guaranteed: 62.3 dB Typical: 71.0 dB at 100 MHz Guaranteed: 56.3 dB Typical: 64.2 dB at 250 MHz Guaranteed: 51.8 dB Typical: 59.1 dB at 500 MHz |
Attenuation to Crosstalk Ratio Far-end [ACRF] | Guaranteed: 38 dB Typical: 54.7 dB at 100 MHz Guaranteed: 30 dB Typical: 46.6 dB at 250 MHz Guaranteed: 24 dB Typical: 40.5 dB at 500 MHz |
Power sum attenuation crosstalk ratio far-end [PSACRF] | 35 dB at 100 MHz 27 dB at 250 MHz 21 dB at 500 MHz |
Near end crosstalk [NEXT] | Guaranteed: 65.3 dB Typical: 85.5 dB at 100 MHz Guaranteed: 59.3 dB Typical: 83.1 dB at 250 MHz Guaranteed: 54.8 dB Typical: 60.1 dB at 500 MHz |
Coupling attenuation | >= 55 dB from 30…100 MHz conforming to IEC 61156-5, ed. 2 type II >= 55 – 20 x log10(f / 100) dB from 100…1000 MHz conforming to IEC 61156-5, ed. 2 type II |
Transfer impedance | <= 50 mOhm/m at 1 MHz (grade 2) <= 1000 mOhm/m at 100 MHz (grade 2) |
Input impedance | 100 Ohm |
Maximum loop resistance | 152.2 Ohm per 1000 m |
Segregation class | Class c conforming to EN 50174-2 |
Maximum resistance unbalance | 2 % |
Pulling force | 120 N |
Bending radius | Minimum bending radius during installation: 8 x overall diameter Minimum bending radius after installation: 4 x overall diameter |
Material | Solid bare copper: conductor PE (polyethylene): wire insulation Aluminium/polyester: foil Tinned copper: drain wire PE (polyethylene): sheath |
Euroclass level | Dca s2 d2 a1 |
Nominal velocity propagation | 76 % |
linear conductor resistance | 76.1 mΩ/m |
AWG gauge | AWG 23 |
Calorific value | 547 MJ/km |
Cable outer diameter | 7.6 mm |
Cable length | 500 m |
Cable weight | 49 kg / 1 km |
Ambient air temperature for installation | 0…50 °C |
---|---|
Ambient air temperature for storage | -20…60 °C |
Ambient air temperature for operation | -20…60 °C |
Directives | 2006/95/EC – low voltage directive 305/2011/EU – construction product regulation |
Flame retardance | LSZH |
Standards | ISO/IEC 11801-ed. 3 performance EN 50173-1 performance EN 50174-1 performance ANSI/TIA/EIA-568-C.2 performance IEC 61156-5-ed. 2.1 performance EN 50288-10-1 performance ISO/IEC 14763-2 installation standards EN 50174-2 installation standards IEC 60332-1 flame propagation characteristics IEC 60754-1 IEC 60754-2 acidity of combustion gases IEC 61034 smoke generation |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 35.000 cm |
Package 1 Width | 40.000 cm |
Package 1 Length | 40.000 cm |
Package 1 Weight | 27.200 kg |
Unit Type of Package 2 | P12 |
Number of Units in Package 2 | 18 |
Package 2 Height | 119.000 cm |
Package 2 Width | 80.000 cm |
Package 2 Length | 120.000 cm |
Package 2 Weight | 489.600 kg |
Reviews
Clear filtersThere are no reviews yet.